Your real-time maintenance

An outside protection against lightning with a lightning rod must be checked every year and after each lightning strike to ensure its good working order. Source: NFC 17-102 – September 2011.

Maintenance solutions

maintenance installation lightning rod

Contact@ir System | Your connected maintenance

Maintenance and servicing of your lightning protection installation are also necessary to preserve your manufacturer's and installer's warranties. To ensure a total security, you must be certain of its efficiency at any time.

Contact@ir® System is an exclusive solution proposed by LPS France® meet normative requirements, preserve your warranties and ensure your security throughout the lifetime of your lightning protection installation.

Diagnostics products lightning

Product Diagnostics

A diagnosis of your installation is made to detect any malfunction.

Real time lightning rod

Real time notifications

You are warned by an alert sent to your smartphone or computer.

Maintenance lightning rod

Optimized maintenance

You can know what type of maintenance to perform according to the problem detected.

Project study lightningYour project is accurate, you have collected a detailed set of dataProject study lightning strike
lightning protection maintenance

Contact@ir System | Your connected maintenance solution

Contact@ir® is a self-sustaining and wireless system of products identification and diagnosis and of lightning strike communication.

A Contact@ir® emitter can be optionally fitted on each Contact@ir® Ready product (Paraton@ir® range and Compt@ir® lightning strike counters).

Then the Contact@ir® emitter permanently communicates the operating status of the Contact@ir® Ready a product as well as its communication liability. The communication is ensured by radio, without any physical link.

LPS France | Contact@ir Operation

This system transmits a real time alert when a lightning strike is detected by the Contact@ir® Ready product. This alert also contains the power level of the sudden lightning strike. A verification and maintenance intervention must be planned according to the importance of lightning strike.

With our system, you can remotely make a first diagnosis. This way, the maintenance service will be optimized, you will avoid unnecessary costs and your lightning protection system will be kept in good working order.

Efficient, reliable and easy-to-use, Contact@ir® System facilitates the control and maintenance of your lightning protection installation.

Contact@ir® System favours lightning risk prevention.

Maintenance lightning installation

Dongl@ir
Contact@ir

The Contact@ir® System used with the Dongl@ir® receiver allows you to check the correct operation of your product when you are on site.

Receiving data

The transmission of datas occurs by radio waves, without any physical link between the Contact@ir® emitter and the Dongl@ir® receiver.

In this way, Dongl@ir® facilitates and makes safer the diagnosis of a product often difficult to access, the intervening person not being constained any more to get into a risky situation to reach it.

Dongl@ir® is a specific mean of diagnosis. It has to be used nearby the product (80 meters maximum).

Within a few seconds, your product is identified and the result of its diagnosis appears on your sceen. You then immediately know if an intervention is necessary on your installation or not.

Dongl@ir specifics

Dongl@ir® is provided in the form of an USB key and is plugged :

- In your pad or Androïd mobile with a micro USB adapter. In that case, the information will be read on the application Contact@ir® App.

- In one of your PC or MAC USB port.In that case, the information will be read on software Contact@ir® Soft.

Rout@ir
Contact@ir

The Contact@ir® system used with the Rout@ir® receiver allows you to check the operation of your product in real time without moving.

Receiving data

If one of your product is struck by lightning, you immediatly receive a warning.

You are given the lightning strike intensity level on a scale from 1 to 3.

It is thus possible to know which type of checking has to be done.

Your products equipped with a Contact@ir® emitter permanently communicates by radio waves with your nearby-located Rout@ir®.

Datas collected by Rout@ir® are constantly transmitted to the server on which they are recorded and dated without any intervention on your part.

The multiplicity of usable networks for the data transmission makes its use possible even in the most isolated places. Datas can be remotely accessed to, from any appliance connected to the internet. At any time and from anywhere, you can peruse the status of you installations.

Rout@ir specifics

Is in the form of a box. It can be supplied on the mains or thanks to a photovoltaic cell. It transmits the datas to the server by the most suitable network.

Request contact

A question remains unanswered even after consulting our Wiki LPS or more generally on our site? You have a precision to ask or a suggestion to make?

Please complete this form by filling out all required fields. We will contact you as soon as possible.